Similar products

JY500A Batching Controller

Batching Controller JY500A picture
JY500A Batching Controller Application: Apply to quantitative batching scales , weighing system of industrial electronic scales, batching control of concrete mixer, bitumen mix process. controller's Features: -Programmable inputs ...
Model: JY500A
Brand: Longxin
Habitat: China
Weight: 700g
Instruction Manuals :

【Download JY500A Batching Controller  Manual 】

Asked price: longxin@meterforall.com
  The detailed introduction of JY500A Batching Controller

Application of controller:
Apply to quantitative batching scales , weighing system of industrial electronic scales, batching control of concrete mixer, bitumen mix process.

controller's Features:
-Programmable inputs and outputs
-Filter time is adjustable
-Selectable analog outputs for data indications such as flowrate, total   and speed.
-Ignores vibration onand around scales
-Digital electronics. Provide accurate, drift-free performance

The Technical parameters of Batching ControllerJY500A

Model

JY500A

Weight

2.5Kg

Non-linearity

≤0.005%FS

Sampling rate

≥200 times/s

Tolerance

-59999~59999 kg

Division

1,2,5,10,20,50 optional

Max.net signal input

≤30mV

Input sensitivity

≥0.5uV

A/D coversion speed

≥600 000

Display

Double line 12 digit LED, 12 state indicator lights

Weighing sensor excitation

DC 10V, 250mA

maximum connect 4 load cells (4-wire)

Analog input

4-20mA, 1 CH, 16 bits, 4-wire connection

Signal input range

+5mv~+25mv

Digital Input              (Out control input)

5 CH, pulling down validates

Digital Output          (Relay output)                

8 CH, 24V/500mA               

Selectable DA output

12 bits, 4-20mA, driving resistance 500Ω (Communication invalidates when DA output works.)

Communication interfaces

RS232<=1.5m RS485<=1000m (DA output invalidates when communication works.)

Ext.Power supply

AC 220V+20%, 50Hz/60Hz, ≤10W

Working temperature

-10-40℃

Humidity

≤85%RH

Dimension

95(W)x 163(D)x 45(H)mm

 

The front panel of JY500A controller

The main control keys of the controller

⒀ [Set] key
Press this key to:
.To confirm the current input by key with save

⒁ [Printing/selection] key
Press this key to:
Select printing or selection.Shift to right digit when setting parameter value

⒂ [Tare] key
Press this key to:
.Tare off the weight of a container when weighing display is positive and stable;
.Increase value at a digit when setting parameter value

⒃ [Zero] key
Press this key to:
.Set weight displayed to zero;
.Decrease value at a digit when setting parameter value

Turning on
When this batching controller is powered on,it will display 888888,then it comes to weighting status.If the unloaded scale divates from zero point but still auto zero range,then controller will come to zero automatically.

Before weighing and batching,make sure that:
a.The load cell signal cable is connected and properly secured.
b.The scale is turned on.

Zero setting
If the current weight is in zero setting range ,press the [zero] key ,then the batching controller will come to zero and zero indicator will be on.

Tare
At batching status,when the current display is positive and stable,the weight is in the tare range,press [TARE] will tare off the current weight and weighing indicator will display 0,zero indicator is on.

The back panel of Batching Controller JY500A

The dimension of JY500A batching controller



Lastest related arcticle abstract
This batching controller product series is applicable to furnace cupola and electric furnace to weigh,distribute and transport the material under manual digital displays.It helps to stabilize ... >>more

View times:

Copyright China LongXin Weighing     About Us | Contact | Partner Site | Sitemap    
longxin@meterforall.com |